Skip to main content
ARS Home » Plains Area » Houston, Texas » Children's Nutrition Research Center » Research » Publications at this Location » Publication #435141

Research Project: Enhancing Childhood Health and Lifestyle Behaviors

Location: Children's Nutrition Research Center

Title: High-resolution peripheral quantitative computed tomography reliability and accuracy of bone density and morphology properties in children

Author
item SHYPAILO, ROMAN - Children'S Nutrition Research Center (CNRC)
item CALARGE, CHADI - Baylor College Of Medicine
item SAHA, PUNAM - University Of Iowa
item ZHANG, XIAOLIU - University Of Iowa
item CHEN, XIAOJIE - University Of Iowa
item DINH, STEPHANIE - Baylor College Of Medicine
item HUANG, XIAOFAN - Baylor College Of Medicine
item ZEMEL, BABETTE - University Of Pennsylvania
item BACHA, FIDA - Children'S Nutrition Research Center (CNRC)

Submitted to: Journal of Bone and Mineral Research
Publication Type: Peer Reviewed Journal
Publication Acceptance Date: 6/6/2025
Publication Date: 6/14/2025
Citation: Shypailo, R.J., Calarge, C., Saha, P., Zhang, X., Chen, X., Dinh, S., Huang, X., Zemel, B.S., Bacha, F. 2025. High-resolution peripheral quantitative computed tomography reliability and accuracy of bone density and morphology properties in children. Journal of Bone and Mineral Research. 9(9). Article ziaf106. https://doi.org/10.1093/jbmrpl/ziaf106.
DOI: https://doi.org/10.1093/jbmrpl/ziaf106

Interpretive Summary: Researchers in Houston, Texas tested a special scan called HR-pQCT to see how well it measures bone health in children. They scanned the arms and legs of healthy kids twice to check if the results stayed the same. The results were very consistent, especially for the lower leg bones. The team also compared these scans to a more detailed lab scan and found they were very similar. A new computer method they used gave very strong and reliable results. Overall, the study shows this scan is a dependable way to study bone strength and structure in children.

Technical Abstract: Volumetric bone density, microarchitecture, and strength measures using HR-pQCT are valuable measures of bone health in pediatrics. Our cross-sectional study evaluated bone measure reproducibility in pediatric participants using repeat HR-pQCT (XtremeCT II, Scanco Medical) scans of non-dominant distal tibia and radius of 30 healthy children and adolescents (7-17 yr, 47% female) by 2 technicians. Additionally, we examined HR-pQCT and micro-CT of 26 cadaveric distal tibia specimens to evaluate agreement between the modalities. All HR-pQCT scans were analyzed using manufacturer-provided software (Image Processing Language, Scanco Medical) and a fully automated, previously validated, in-house algorithm, offering measures of bone microstructure (eg, trabecular plate-rod distribution, transverse trabeculae, trabecular bone strength) currently unavailable in the manufacturer-provided software. Root-mean-squared percent coefficient of variation (RMS-%CV) assessed precision and least significant change. Intraclass correlation coefficients (ICCs) using absolute-agreement, 2-way random-effects models assessed reliability. Pearson’s correlation coefficients and ICC assessed linear relationships and agreements between HR-pQCT and micro-CT, respectively. In children and adolescents, RMS-%CV of HR-pQCT-derived trabecular bone measures at distal tibia and radius ranged from 0.8-4.4 to 0.8-6.0, respectively. Most cortical bone results were in a similar range. Both computational algorithms showed ICC > 0.90. RMS-%CV and least significant change values were lower for tibia than radius. ICCs were lower for cortical than trabecular outcomes. Most cadaveric results showed ICC > 0.83, other than trabecular bone thickness and modulus (ICC = 0.7). Pearson’s r (>0.86) suggested strong correlations for almost all parameters. HR-pQCT and micro-CT results using in-house algorithm did not differ significantly, while manufacturer-provided algorithm results showed lower yet still moderate reliability (ICC > 0.55). Reliability of the second-generation HR-pQCT in pediatric participants is excellent—better in tibia vs radius. Our results support the high reproducibility of XtremeCT II scans and thus the use of this clinical imaging modality in studies of pediatric bone health.