Skip to main content
ARS Home » Pacific West Area » Hilo, Hawaii » Daniel K. Inouye U.S. Pacific Basin Agricultural Research Center » Tropical Pest Genetics and Molecular Biology Research Unit » Research » Publications at this Location » Publication #431445

Research Project: Advancing Molecular Pest Management, Diagnostics, and Eradication of Fruit Flies and Invasive Species

Location: Tropical Pest Genetics and Molecular Biology Research Unit

Title: Applying PCR cycle autonormalization to PacBio full-length 16S rRNA library preparations: Impacts on error rates and sequence distributions

Author
item Mason, Charles
item WEAVER, MIKINLEY - Orise Fellow
item Kissinger, Karma
item Johnson, Melissa
item Copeland, Duan
item Anderson, Kirk
item Geib, Scott

Submitted to: mSphere
Publication Type: Peer Reviewed Journal
Publication Acceptance Date: 5/26/2026
Publication Date: 6/22/2026
Citation: Mason, C.J., Weaver, M., Kissinger, K.R., Johnson, M.A., Copeland, D.C., Anderson, K.E., Geib, S.M. 2026. Applying PCR cycle autonormalization to PacBio full-length 16S rRNA library preparations: Impacts on error rates and sequence distributions. mSphere. 11. Article e00295-26. https://doi.org/10.1128/msphere.00295-26.
DOI: https://doi.org/10.1128/msphere.00295-26

Interpretive Summary: Amplicon-based sequencing of the 16S rRNA gene has greatly aided the study of bacterial communities. Improvements in read quality and the sequence output in third-generation sequencing technologies have a potential to improve resolution of difficult to distinguish taxa. These techniques rely on PCR-based amplification. One issue that can arise in the generation of sequencing libraries is the copy number can vary wildly between specimen types, which can create a scenario where the optimal number of PCR cycles differs between samples. Here, we demonstrate that controlling PCR cycles through cycle autonormalization greatly improves the performance of PacBio Kinnex sequencing by reducing PCR-introduced errors in amplification. Furthermore, cycle autonormalization has the potential to improve workflows by allowing equal pools of different sample types without the need to quantify or normalization plates before pooling amplicons. These methods are particularly useful to laboratories handling different specimen types with wide ranges in 16S copies.

Technical Abstract: The bacterial 16S rRNA gene is used extensively for the study of host and environment microbiomes. These approaches have most often relied on sequencing partial fragments of the 16S (250-400bp). Improvements to PacBio sequencing in both quality and yield may provide additional sequence resolution while improving sampling depth. Despite this, PCR-based errors remain an outstanding issue, and this could be further compounded with these techniques due to a five-fold increase in sequence coverage. Here, we addressed the issue of overamplification of PCR and evaluated how seven different specimen types performed under four different cycling procedures. We compared conventional PCR at different cycle thresholds (20, 24, 30) to PCRs that were automatically terminated on a per-sample basis by amplification thresholds (autonormalization) on the iconPCR instrument. Samples that were autonormalized had fewer errors and chimeric sequences compared to other cycling protocols, improved end-sequence yields, and had a more-even sequence distribution of samples. Substitution-based errors were more evident in samples that were overamplified (30 cycles) compared to autonormalized protocols. Sample loss due to number of PCR cycles were not equal across all specimen types, with the more diverse samples being more sensitive to sequence losses through sequence processing pipelines. Overall, our results demonstrate that autonormalization protocols improve PacBio Kinnex sequencing by reducing PCR introduced errors in over cycling, while ensuring all samples receive a minimal amount of amplification. The differential impacts between sample types are valuable.