Location: Poultry Research
Title: Effect of photometric sensor orientation on the measurement of light illuminance (intensity) in commercial broiler houses during tunnel ventlationAuthor
![]() |
DAVIS, J - Auburn University |
![]() |
LINHOSS, J - Auburn University |
![]() |
WESTERLUND, W - Auburn University |
![]() |
Purswell, Joseph |
![]() |
EDGE, C - Auburn University |
|
Submitted to: Applied Engineering in Agriculture
Publication Type: Peer Reviewed Journal Publication Acceptance Date: 10/25/2024 Publication Date: 11/25/2024 Citation: Davis, J., Linhoss, J., Westerlund, W., Purswell, J.L., Edge, C. 2024. Effect of photometric sensor orientation on the measurement of light illuminance (intensity) in commercial broiler houses during tunnel ventlation. Applied Engineering in Agriculture. 40(6): 651-658. https://doi.org/10.13031/aea.16066. DOI: https://doi.org/10.13031/aea.16066 Interpretive Summary: Light intensity is an important environmental factor for commercial poultry production. Measuring and maintaining light intensity at recommended levels can be challenging when sunlight enters through the exhaust fans. Light dimmer settings for the artificial lighting system are adjusted using common light meters which often cannot accurately account for sunlight intrusion. The goal of this study was to determine how to incorporate the effect of sunlight intrusion on visible light levels in a commercial broiler house. Light intensity measurements were collected in commercial broiler houses with sensors at five different orientations at multiple locations within the building. The results showed that the conventional method of measuring light intensity from directly overhead significantly underestimated the amount of visible light available to the birds during tunnel ventilation. For the houses used in this study, less than half of the house area was operating at the target light intensity, with the remaining area operating above the recommended level. Accurately measuring light intensity to account for directional effects from all light sources is important to understand and manage the light environment in a commercial broiler house. Technical Abstract: The measurement of illuminance (light intensity) in commercial broiler houses has typically been performed with photometric meters placed on the floor with the sensor facing the ceiling. This orientation is useful in adjusting light intensity from bulbs but does not have the field of view to account for light intrusion through the tunnel fans that may affect bird activity. The objective of this study was to evaluate the effect of sensor orientation on the measurement of light intensities in commercial broiler houses during tunnel ventilation. A commercial broiler farm with four 18.3 x 182.9 m modern broiler houses (n=3) in south-eastern Alabama was used. Four 45 cm tall stands were constructed to measure light intensity at bird height in five directions [evaporative pad end wall, fan end wall, both sidewalls, ceiling] at each of 76 measurement locations. Target light intensity was set at 0.2 lux. Directional light intensity measurements were simultaneously taken down the length of each house near solar noon (± 1 hr) with all tunnel fans operating. Descriptive statistics were calculated using PROC FREQ and graphs were generated with SGPLOT in SAS. The current method of using ceiling-facing photometric sensors to quantify light illuminance trends in broiler houses is underestimating the light intensities that birds experience. At the center of the house width near the fans, ceiling-facing sensors captured approximately 15.7% of the maximum light ingress (measured by north-side wall sensors facing the tunnel fans). The sensors facing the fan end wall showed that light ingress influences approximately 42.6% of the floor area at the fan end of the house; four times previously reported by ceiling-facing sensors. This study has shown that mapping light intensity in five directions for each location provides an improved understanding of the maximum light intensity the birds may be experiencing compared to the current ceiling-facing sensor or other single orientation method. For the described modern broiler houses tested during tunnel ventilation, only 46% of the house length was controlled by the lighting system near company-specified target intensities. Light ingress from operating tunnel fans and the evaporative cooling system increased light intensities above target across 54% of the house length. Important photometric sensor orientations to capture maximum light intensities may vary depending on your measurement location, house design and orientation, tunnel fan size and location, time of day and season, and specified company target intensities. |