Skip to main content
ARS Home » Southeast Area » Oxford, Mississippi » National Sedimentation Laboratory » Water Quality and Ecology Research » Research » Publications at this Location » Publication #414983

Research Project: Enhancing Long-Term Agroecosystem Sustainability of Water and Soil Resources Through Science and Technology

Location: Water Quality and Ecology Research

Title: USDA LTAR common experiment measurement: Dissolved nitrate (NO3-) concentration

Author
item Lizotte Jr, Richard
item Pisani, Oliva
item Veum, Kristen
item Kovar, John
item Malone, Robert
item Cole, Kevin

Submitted to: Protocols.io
Publication Type: Research Notes
Publication Acceptance Date: 12/3/2024
Publication Date: 12/4/2024
Citation: Lizotte Jr, R.E., Pisani, O., Veum, K.S., Kovar, J.L., Malone, R.W., Cole, K.J. 2024. USDA LTAR common experiment measurement: Dissolved nitrate (NO3-) concentration. Protocols.io. 1-7. https://doi.org/10.17504/protocols.io.4r3l2qm1pl1y/v1.
DOI: https://doi.org/10.17504/protocols.io.4r3l2qm1pl1y/v1

Interpretive Summary: Nitrate (NO3-) is a form of nitrogen (N) that is of interest in surface and groundwater. Nitrate often occurs in trace amounts (<0.01 mg/L) in rivers and lakes but can reach high levels in some surface water and groundwater. In excessive amounts, it can elicit an illness known as methemoglobinemia in infants, and the drinking water standard is limited to 10 mg NO3--N/L to prevent this illness. In addition, NO3- is an essential nutrient for growth and photosynthesis in aquatic autotrophs, and elevated NO3- loading contributes to eutrophication and hypoxia of surface waters, particularly in coastal marine ecosystems. The recommended methods for measuring NO3- concentration in water include the colorimetric cadmium reduction method, whereby NO3- is reduced to nitrite (NO2-) in the presence of cadmium. A highly colored azo dye is produced and measured colorimetrically. An alternative enzymatic method utilizes “greener” chemistry by replacing the toxic copper-based cadmium with nitrate reductase in combination with two coenzymes to reduce NO3- to NO2-, followed by the identical colorimetric quantification reaction used in the cadmium method.

Technical Abstract: Nitrate (NO3-) is an ionized form of nitrogen (N) that is of interest in surface and groundwater. Nitrate often occurs in trace amounts (<0.01 mg/L) in rivers and lakes but can reach high levels in some surface water and groundwater. In excessive amounts, it can elicit an illness known as methemoglobinemia in infants, and the drinking water standard is limited to 10 mg NO3--N/L to prevent this illness. In addition, NO3- is an essential nutrient for growth and photosynthesis in aquatic autotrophs, and elevated NO3- loading contributes to eutrophication and hypoxia of surface waters, particularly in coastal marine ecosystems. The recommended methods for measuring NO3- concentration in water include the colorimetric cadmium reduction method, whereby NO3- is reduced quantitatively to nitrite (NO2-) in the presence of cadmium. A highly colored azo dye is produced and measured colorimetrically. An alternative enzymatic method utilizes “greener” chemistry by replacing the toxic copperized cadmium with nitrate reductase (specifi cally, AtNaR2) in combination with two coenzymes (nicotinamide adenine dinucleotide and nicotinamide adenine dinucleotide phosphate) to reduce NO3- to NO2-, followed by the identical colorimetric quantifi cation reaction used in the cadmium method. This enzyme reduction method overcomes interferences from phenolics and humic substances noted in earlier enzymatic methods. The method detection levels (or limits; MDL) for standard and low NO3- + NO2- concentrations with enzyme reduction are comparable to the long-term MDLs of the continuous-fl ow analyzer method with cadmium reduction. In addition, NO3- concentration differences were statistically equivalent to zero or analytically equivalent to zero (i.e., concentration differences were less than MDLs (Patton and Kryskalla, 2011)). Recent advances in fi eld sensor technology have afforded commercial sensors that allow for in situ NO3- measurement using an optical sensor. These sensors can record values over short durations (seconds to minutes) and use an ultraviolet spectrophotometer (Johnson and Coletti, 2002). Although these sensors provide high-resolution data, their accuracy can degrade because of background-colored dissolved organic matter (DOM) and high turbidity. Conduct water sample collection and lab analyses at least monthly at varied fl ow rates to validate sensor readings.