Animal Metabolism-Agricultural Chemicals Research Site Logo
ARS Home About Us Helptop nav spacerContact Us En Espanoltop nav spacer
Printable VersionPrintable Version     E-mail this pageE-mail this page
Agricultural Research Service United States Department of Agriculture
Search
  Advanced Search
 
Programs and Projects
Subjects of Investigation
 

Title: DETERMINATION OF RACTOPAMINE IN CATTLE AND SHEEP URINE USING BIOSENSOR

Authors

Submitted to: Meeting Abstract
Publication Type: Abstract Only
Publication Acceptance Date: January 1, 2003
Publication Date: September 10, 2003
Citation: Shelver, W.L., Smith, D.J. 2003. Determination of ractopamine in cattle and sheep urine using biosensor. VII International Conference on Agri-Food Antibodies, September 10-13, 2003, Uppsala, Sweden.

Technical Abstract: A biosensor method, using the surface plasmon resonance (SPR) principle, was developed for the determination of ractopamine in cattle and sheep urine. A monoclonal antibody was used to compete with ractopamine in the sample and ractopamine immobilized on the sensor chip. Addition of bovine serum albumin (BSA, 1 mg/mL) as antibody stabilizer to the incubation buffer was required to achieve a stable biosensor response throughout each sample set. The calibration curve gave a mean IC50 of 4.7 +/- 0.21 ng/mL (n = 7). Over sample concentrations from 2.5 to 10 ng/mL recoveries were typically approximately 100-110% while inter and intra assay reproducibility (% CV) was usually less than 10% and 6% respectively. Comparison of biosensor results with results obtained from high performance liquid chromatography (HPLC) and enzyme linked immunosorbent assays (ELISA) using enzyme-hydrolyzed urine (to convert ractopamine conjugates to free ractopamine) gave correlation coefficients of 0.94 for sheep and 0.86 for cattle. Slopes of the lines, with zero intercepts, equaled 0.80 for sheep and 0.74 for cattle. For untreated (non-hydrolyzed) urine samples, the correlation between biosensor and HPLC results was 0.95 for sheep or 0.72 for cattle with a slope of 1.18 (sheep) or 1.69 (cattle). The slopes greater than unity indicate that the biosensor responded to ractopamine metabolites in addition to free ractopamine. The biosensor assay is an excellent analytical tool to determine ractopamine residues in sheep or cattle urine, and the results should be extendible to other species with suitable validation.

   
 
 
Last Modified: 05/19/2013
ARS Home | USDA.gov | Site Map | Policies and Links 
FOIA | Accessibility Statement | Privacy Policy | Nondiscrimination Statement | Information Quality | USA.gov | White House