Research Project: Evaluation of Low-Temperature Drying and Aeration Monitoring and Control System

Location: Engineering and Wind Erosion Research Unit

2011 Annual Report


1a.Objectives (from AD-416)
1) Determine the effectiveness of temperature and rh sensors for monitoring grain conditions during low temperature drying. 2) Monitor insect populations and temperatures at different depths of the corn in bins after drying, using the Insector system and compare the effects of drying treatments.


1b.Approach (from AD-416)
Our previous research with sensors that use relative humidity and temperature to predict grain equilibrium moisture content (EMC) has shown that they require equilibrium conditions to exist between the grain and interstitial air for accurate measurements. The OPI-Integris grain monitoring system includes in-bin, multi-point sensors for relative humidity and temperature to predict grain EMC. Previous collaboration between ARS and OPI-Integris used this system to monitor rice aeration with some success. Research is needed to determine the accuracy of this method during non-aeration periods when the grain is equilibrating with air conditions. Grain monitoring cables create increased point loads on roofs during bin loading and unloading. Cables with sensors attached may create greater forces on the roof than conventional cables. Research is needed to determine the magnitude of roof forces with these cables.

Either corn or sorghum at 18% moisture content will be loaded into three bins at the Center for Grain and Animal Health Research (CGAHR) for drying with computer controlled low-temperature drying systems. The control system will monitor ambient temperature and relative humidity and grain EMC at multiple points in the drying bins using temperature and relative humidity sensors. The fans and heaters will be operated using the grain conditioning program, Integris Pro. The grain will be regularly probed to sample grain near moisture sensors for validation of readings and modeling. The moisture content of samples will be determined by oven drying and with a moisture meter. EMC curves will be determined for the tested corn and compared to published data. The Integris Pro Model will be used for prediction of end moisture and temperature conditions.

Samples will be taken from the corn before it is dried and during storage after drying. These samples will be infested with maize weevils and held in an environmental chamber at optimum temperature and humidity for insect development. Progeny production in different lots of corn will be compared. The Insector System will be used to monitor insect populations during storage, examine bin-cooling patterns and different depths of the corn, and estimate when corn is most likely to become infested during the spring months following initial storage. Data will be integrated into Expert Systems for grain storage.


3.Progress Report

Cable load tests were conducted in two concrete storage bins, 15-ft diameter by 85-ft maximum depth, in the CGAHR research elevator, using 75-ft long cables suspended from the center of the bin and from a point 1.5-ft from the bin sidewall. Five different cables were tested -- with four different cross-sectional areas, and two samples of the smallest size both with and without small sensors protruding every 6' along the cable. Two replications of the tests were conducted with both wheat and corn at the center location during filling and emptying with a grain flow rate of about 2800 bu/h, giving a grain velocity on the cables of about 4 in/min. Only wheat was tested with cables at the side location. The lower end of the cables were weighted but were not restrained. Forces on the cables were monitored with load cells and a data acquisition system during loading and unloading of the bins. The peak loads were during emptying with cables at the center of the bin. These emptying loads were generally from 50% to 100% larger than the corresponding loads during grain filing. The largest loads were about 1000 lb and generally occurred with larger diameter cables. These results can be used by designers to understand the effect of grain type, cable size and design, and center versus sidewall cable locations on the loads experienced by temperatures cables in grain storage bins.

ADODR monitoring was performed by site visits, e-mails, phone calls, and personal interactions.